CS-1 Gyratory Sifter Maintenance

Monthly Sanitation & Maintenance for the CS-1 Gyratory Sifter

*Add grease to the (3) grease fittings: Lower spindle, Base bearing, Bearing housing plug.

*Every 25-28 days the CS-1 sifter decks and screen insert frames need to be disassembled and thoroughly cleaned & sanitized.

Step 1. Remove the clamps and connection sleeves from the top inlet and bottom discharge outlets.

Step 2. Dismantle the (4) hold down rods by removing the nut and bracket with a